Proccess safety BEACON – APRIL 2021

A recent event in Gainesville, Georgia, US, involved a significant leak of liquid nitrogen. A poultry processing plant used liquid nitrogen to quickly freeze chicken products. This freezing system had only been in operation for 4 6 weeks before the event. Six workers...

read more

Proccess safety BEACON – March 2021

On April 12, 2004, a company in Dalton Georgia, USA was contracted to make triallyl cyanurate. A runaway reaction occurred, and flammable and toxic allyl alcohol and allyl chloride were released to the atmosphere. Some material was released through a poorly sealed...

read more

Proccess safety BEACON – FEBRUARY 2021

A U.S. company had fires at 2 of its locations about 100 days apart. Both were caused by static sparks igniting flammable liquids and vapors. On July 17, 2007, flammable VM&P naphtha was being transferred from a tank truck to a vertical 15,000 gallon (57 m3 )...

read more

Proccess safety BEACON – JANUARY 2021

An operator was adding a raw material from many drums. All the drums were black with white ends and had blue & white labels. After adding ~20 drums, the operator noticed a drum that had a different name on it. Same black and white drum, same blue and white label....

read more

Proccess safety BEACON – December 2020

Do you think that you do not have to worry about potential reactive chemistry incidents because your workplace has no intentional chemical reactions? Don’t be fooled – reactive chemistry  incidents can happen almost anywhere. Here are two examples. On November 7,...

read more

New version of Technical pamphlet #7 on Explosions

The CRAIM has just published a new version (2ed.) of its Technical Popularization Pamphlet # 7 on "Explosion".  This version contains new information on Heat induced tears (HIT). A heat induced tear (HIT) is a rupture of a NON-PRESSURE tank containing flammable...

read more

Info CRAIM – Fact sheet #1

Following the publication of the Environmental Emergency Regulations, 2019 (SOR/2019-51), specifically the new companion document `` Technical Guidelines for the Environmental Emergency Regulations 2019'' from Environment Canada, the CRAIM with its new Sheet # 1...

read more

Proccess safety BEACON – November 2020

Some equipment such as vibratory conveyors and screens are meant to move, but in most other equipment, vibration is not desirable. It can lead to piping and equipment damage including premature failure. A new compressor system was starting operation (Diagram A) The...

read more